期刊文献+

循环流化床烟气脱硫吸收塔塌床原因分析及处理措施

Analysis of the Causes and Treatment Measures for the Collapsed Bed of the CFB Flue Gas Desulfurization Absorption Tower
下载PDF
导出
摘要 循环流化床烟气脱硫吸收塔是工业企业生产的主要设备之一,吸收塔塌床后从一定程度上致使塔内压降不稳定,制约了工业企业的生产进度。基于此,本文以某公司的循环流化床烟气脱硫系统为主要研究对象,介绍了其主要的工作机理,结合实际情况对吸收塔塌床进行了分析,并有针对性地提出了吸收塔塌床的主要处理措施,希望能够给同行带来一定的帮助。 The circulating fluidized bed flue gas desulfurization absorption tower is one of the main equipments produced by industrial enterprises.This paper takes the circulating fluidized bed flue gas desulfurization system of a limited company as the main research object.First,its main working mechanism is introduced;secondly,the collapsed bed of the absorption tower is analyzed in combination with the actual situation;The main treatment measures of the bed,hoping to bring some help to the peers.
作者 田亚军 Tian Ya-jun
出处 《电力系统装备》 2022年第4期115-117,共3页 Electric Power System Equipment
关键词 循环流化床 烟气脱硫塔 床层压降 circulating fluidized bed flue gas desulfurization tower bed pressure drop