摘要
介绍了南京三山街高效制冷空调系统的设计思路。设计中空调冷源系统、输配系统及控制系统等采用了节能措施,使制冷机房系统综合能效比达到了5.86。结合工程设计,总结了适合商业项目的高效制冷空调系统的精细化设计方法。
The design ideas for high-efficiency refrigeration and air conditioning system in Sanshan street,Nanjing is presented.In this design,energy saving measures are adopted in the air conditioning cold source system,transmission and distribution system and control system,so that the comprehensive energy efficiency ratio of the refrigerator room system reaches 5.86.Combined with engineering design,the refined design method of high-efficiency refrigeration and air conditioning systems suitable for commercial projects is summarized.
作者
简亚婷
陈刚
贾沛
张烽
周强
赵小虎
Jian Yating;Chen Gang;Jia Pei;Zhang Feng;Zhou Qiang;Zhao Xiaohu(East China Architectural Design and Research Institute Co.,Ltd.,Shanghai;China Resources Land Limited(CR Land),Shenzhen)
出处
《暖通空调》
2022年第4期47-51,共5页
Heating Ventilating & Air Conditioning
关键词
高效制冷空调系统
商业建筑
大温差
水系统
节能
能效比
high efficiency refrigeration and air conditioning system
commercial building
large temperature difference
water system
energy saving