摘要 为了从根本上预防和治理钢管塔微风振动问题,从设计、加工、安装等方面简要分析某高压线路钢管塔板件开裂的原因,并从结构设计的角度提出钢管塔微风振动的预防措施,同时根据以往研究成果以及工程应用经验,对运行线路钢管塔的微风振动给出具体的治理措施。 In order to prevent and control the wind vibration of steel tube tower fundamentally,this paper briefly analyzes the reasons for the cracking of steel pipe tower plates of a high-voltage line from the aspects of design,processing,and installation,and proposes preventive measures for the breeze vibration of steel pipe towers from the perspective of structural design.Based on previous research results and engineering application experience,The breeze vibration of the steel tube tower gives specific treatment measures.
作者 侯中伟 魏鹏 高琦 李显鑫 HOU Zhong-wei;WEI Peng;GAO Qi;LI Xian-xin(State Grid Economic and Technology Research Institute Co.,Ltd.,Beijing 102209,China;Northwest Electric Power Design Institute Co.,Ltd.of CPECC,Xi'an 710075,China)
出处 《电力勘测设计》 2022年第5期17-23,共7页 Electric Power Survey & Design
关键词 钢管塔 微风振动 板件开裂 防治措施 steel pipe tower breeze vibration plate cracking prevention and control measures