期刊文献+

300 MW切缸供热机组调节能力试验研究

Experimental Study on Regulation Capacity of 300 MW Heat⁃supply Steam Turbine Unit with LP Cylinder Removed
下载PDF
导出
摘要 切缸供热机组的调节能力受实际运行参数的影响,设计抽汽工况图不能准确反应机组的实际调节性能,为解决上述问题,以某300 MW切缸供热机组为例,通过调节能力试验得到机组在不同运行方式下的实际调峰能力与供热能力,并与设计抽汽工况图进行比较,分析实际值和设计值偏差的原因,为发电企业运行调度提供参考。 The regulation capacity of the cylinder cut-off heating unit is affected by steam extraction parameters.The design steam extraction working condition diagram can not accurately reflect the actual regulation performance of the unit.In order to solve this problem,take a 300 MW cylinder cut-off heating unit as an example,the actual peak shaving capacity and heating capacity of the unit under various operation modes are obtained through the regulation capacity test,and compared with the design steam extraction working condition diagram to analyze the reasons for the deviation between the regulation actual value and the design value,so as to provide reference for the operation dispatching of power generation enterprises.
作者 张彦鹏 李思 祝令凯 韩悦 商攀峰 ZHANG Yanpeng;LI Si;ZHU Lingkai;HAN Yue;SHANG Panfeng(State Grid Shandong Electric Power Research Institute,Jinan 250003,China)
出处 《山东电力技术》 2022年第5期63-67,80,共6页 Shandong Electric Power
基金 山东省自然科学基金青年基金(ZR2020QE199) 山东电力研究院科技项目“机组切缸运行特性研究”(ZY-2021-21)。
关键词 切缸供热机组 供热能力 调峰能力 抽汽工况图 thermal power unit with low pressure cylinder cutting off heating capacity peak-regulating capacity steam extraction working condition diagram
  • 相关文献

参考文献9

二级参考文献51

共引文献87

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部