摘要
防爆区域划分是燃机电厂项目的重要组成部分,事关电厂的安全和工程投资的合理规划。根据规程规范的要求,结合增城H级燃气-蒸汽联合循环机组设计经验,提出燃机电厂典型区域的爆炸危险场所防爆分区范围,为其他工程提供参考。
Hazardous areas classification plays an important part in gas turbine power plant project,which is related to the plant safety and engineering investment.According to the requirements of regulations and specifications,combined with the design of Zengcheng level-H gas steam combined cycle unit,the typical hazardous areas classification of gas turbine power plant is put forward which can provide reference for other projects.
作者
张怡
范勇刚
王金成
Zhang Yi;Fan Yong-gang;Wang Jin-cheng(Southwest Electric Power Design Institute,Chengdu,Sichuan,610056)
出处
《电气防爆》
2022年第2期32-36,共5页
Electric Explosion Protection
关键词
燃机电厂
可燃气体
防爆危险区域划分
gas turbine power plant
combustible gas
hazardous areas classification