某电厂屏式再热器弯管出现泄漏,为查明失效原因,采用宏观检查、取样进行金相、力学性能、胀粗率等试验分析确定失效原因,得出管排出列是爆管的直接原因,烟气冲刷、材质老化、性能下降是重要因素,从锅炉运行及日后检验工作等方面提出合理措施及建议。
There were leaks in the screen reheater elbow in a power plant.The causes of the failure was confirmed by macro inspection,sampling and analysis of metallography,mechanical properties,expansion rate.Measures and suggestions were proposed on the boiler operation,the future inspection and other aspects.
作者
侯兴隆
关鹏
刘欣
董志臣
孙旭
赵婧琦
HOU Xing-long;GUAN Peng;LIU Xin;无(Datang Northeast Electric Power Test&Research Institute;Datang Changchun No.2 Thermal Power Co.,Ltd.;Liaoning Datang Int.Jinzhou Thermal Power Co.,Ltd.)
出处
《电站系统工程》
2022年第3期26-28,共3页
Power System Engineering
关键词
屏式再热器
金相
力学性能
失效原因
措施及建议
screen reheater
metallography
mechanical properties
causes of failure
measures and suggestions