期刊文献+

天然水体总磷测定的消解方法改进研究 被引量:1

Optimized study on dissolving method of determining total phosphorus in natural water system
下载PDF
导出
摘要 水体中总磷的含量是测定水质的一项重要指标。本文针对硫酸-硝酸、过硫酸钾-高温高压消解法的缺陷,研究发现过硫酸钾-消解仪法可以缩短消解时间且操作方便、水样及试剂用量少。过硫酸钾-消解仪法的消解优化条件为:水样5.00mL、K_(2)S_(2)O_(8)投加量为1.5mL、消解温度150℃、消解时间70min,消解效果与硫酸-硝酸消解法一致。 The content of total phosphorus in water is an important index to determine water quality.In this paper,in view of the defects of sulfuric acid-nitric acid,potassium persulfate-high temperature and high pressure digestion method,the study found that potassium persulfate-digestion apparatus method can shorten the digestion time,convenient operation,less water sample and reagent consumption.The optimal digestion conditions of potassium persulfate digestion apparatus method were as follows:water sample 5.00mL,potassium persulfate dosage1.5mL,digestion temperature 150℃,digestion time 70min,and the digestion effect was consistent with that of sulfuric acid and nitric acid digestion method.
作者 何雪 张颖 徐婉莹 张文雅 赵业军 HE Xue;ZHANG Ying;XU Wan-ying;ZHANG Wen-ya;ZHAO Ye-jun(Wuhan Donghu College,School of Life Sciences and Chemistry,Wuhan 430212,China)
出处 《化学工程师》 CAS 2022年第5期27-29,共3页 Chemical Engineer
基金 武汉东湖学院大学生创新创业训练计划项目(XC2021056)。
关键词 总磷 天然水体 消解 优化 total phosphorus natural water bodies digestion optimization