摘要
研究了煤炭地下气化废水(UCGW)的多级A/O生化VTBR+催化电解组合处理工艺,分析了催化电解过程中槽电压、pH、液体催化剂、曝气量和反应时间对化学需氧量(COD)去除的影响,给出了最佳催化电解条件下VTBR+催化电解组合工艺的最优运行参数,为高效处理UCGW开发了新的工艺技术。
A multi-stage A/O biochemical VTBR+catalytic electrolysis process for the treatment of underground coal gasification wastewater(UCGW)is studied,and the effects of tank voltage,pH value,liquid catalyst,aeration rate and reaction time on the removal of chemical oxygen demand(COD)in the process of catalytic electrolysis are analyzed.The optimal operating parameters for the VTBR+catalytic electrolysis process under the optimal catalytic electrolysis conditions are obtained,which is a new process technology developed for the efficient treatment of UCGW.
作者
杜明俊
张朝阳
王璇
周一卉
周集体
马克迪
DU Ming-jun;ZHANG Chao-yang;WANG Xuan;ZHOU Yi-hui;ZHOU Ji-ti;MA Ke-di(North China Company,China Petroleum Engineering and Construction Corp.,Renqiu 062552,China;Dalian University of Technology,Dalian 116000,China)
出处
《现代化工》
CAS
CSCD
北大核心
2022年第5期233-238,共6页
Modern Chemical Industry
基金
中国石油天然气集团公司重大科技专项(2019E-25JT)。
关键词
UCG
VTBR
催化电解
生物处理
underground coal gasification
VTBR
catalytic electrolysis
biological treatment