期刊文献+

Temperature Responses to External Heat Fluxes of the Power Distribution System on Alpha Magnetic Spectrometer

原文传递
导出
摘要 High-temperature warnings frequently occurred at the Power Distribution System(PDS)of the Alpha Magnetic Spectrometer(AMS).To investigate the fundamental reasons,a theoretical model for the AMS PDS was established under the International Space Station(ISS)normal and special operating conditions.With the model,the study investigated the external heat fluxes and the temperature responses of the PDS.The effects of ISS special operations on the PDS’s thermal environment were also investigated.Results reveal that the total external heat flux at the PDS reaches its maximum value when the angleβis around–25°,where high-temperature warning frequently occurs.Under the ISS normal operating condition,the temperature response hysteresis at the PDS varies from 116 s to 230 s.When the ISS performed special operations,locking the ISS solar arrays had the greatest influence on the PDS’s external heat fluxes,and the average temperature at the PDS fell by 1.7°C.When the ISS performed multiple special operations,simultaneously locking the ISS solar arrays and adjusting the ISS flight attitude were the most frequent operations,of which the influences on the PDS temperature were the largest,i.e.,the changes in peak temperature reached up to+2.5°C.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第3期802-815,共14页 热科学学报(英文版)
基金 support from Shandong University sponsored by the Fundamental Research Fund of Shandong University,China。
  • 相关文献

参考文献4

二级参考文献16

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;