建立了一种快速溶剂萃取-Florisil固相萃取柱净化-GCMS-QP2020NX检测土壤中有机氯农药的分析方法。测定结果表明:土壤中8种有机氯农药目标化合物的相关系数均为0.9999,平均响应因子的RSD达到1.4%~6.5%,满足HJ835的质控要求,方法检出限在0.002~0.003 mg/kg,测定下限在0.008~0.012 mg/kg,满足HJ168要求。该方法前处理简单,内标法定量结果准确,适用于土壤中有机氯的分析检测。可供参考。
In this paper,a rapid solvent extraction-Florisil solid phase extraction column purification-GCMS-QP2020NX method was established for the determination of organochlorine pesticides in soil.The results show that the correlation coefficients of the 8 organochlorine pesticide target compounds in soil were 0.9999,and the RSD of the average response factor reached 1.4%~6.5%,meeting the quality control requirements of HJ835.The detection limit of the method was 0.002-0.003mg/kg,and the lower limit of determination was 0.008-0.012mg/kg,meeting the requirements of HJ168.The method is simple in pretreatment and accurate in quantitative results by internal standard method.It is suitable for the analysis and detection of organochlorine in soil.
作者
陈秀娜
Chen Xiuna(Shandong Liaocheng Ecological Environment Monitoring Center,Liaocheng,Shandong 252000,China)
出处
《绿色科技》
2022年第10期138-140,共3页
Journal of Green Science and Technology
关键词
土壤
有机氯农药
平均响应因子
检出限
soil
organochlorine pesticides
average response factors
detection limit