摘要 锂离子电池的回收符合国家能源战略需求。在回收的过程中,需对Li^(+)的浓度进行测定,以便于锂的二次利用。采用紫外分光光度法对溶液中的Li^(+)浓度进行了测定,考察了锂配合物紫外吸收峰、反应时间、重现性等测定条件对Li^(+)的质量浓度测定的影响,得到了吸光度A与Li^(+)的浓度c的回归曲线:A=0.2935c+0.5361,r^(2)=0.9962,且重现性实验相对标准偏差(RSD)为0.9%(n=8),同时在3次无水LiCl的样品测定中标准差分别为0.0145%、0.2466%、0.2317%。这种方法测试准确,且避免了大型仪器的场地和操作要求,为Li^(+)的检测提供了更简捷快速的测定方法。 The recovery of lithium ion batteries meets the needs of the national energy strategy.During recovery,the concentration of Li^(+)is determined to facilitate secondary utilization of lithium.In this paper,the concentration of Li^(+)in solution was determined by ultraviolet spectrophotometry.The effects of determination conditions such as ultraviolet absorption peak of lithium complex,reaction time,and repeatability on the determination of Li^(+)content were investigated.The regression curve of absorbance A and concentration c of Li^(+)was obtained:A=0.2935c+0.5361,r^(2)=0.9962,and the relative standard deviation(RSD)was 0.9%.The test results were accurate,and the requirements of large-scale instruments for site operation were avoided.This method is simple and rapid,and can be used in the detection of Li^(+).
作者 王少冕 李鑫 李印 乔骞 王坤 于洪浩 WANG Shao-mian;LI Xin;LI Yin;QIAO Qian;WANG Kun;YU Hong-hao(School of Materials Science and Engineering,Shenyang Ligong University,Shenyang Liaoning 110158,China)
出处 《辽宁化工》 CAS 2022年第6期733-735,739,共4页 Liaoning Chemical Industry
基金 辽宁省自然基金项目(项目编号:20180550902、2019-ZD-0258)。
关键词 锂离子电池 紫外分光光度法 快速检测 正极材料 Lithium-ion battery UV spectrophotometry Rapid detection Cathode material
  • 相关文献

参考文献6

二级参考文献33

共引文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部