结合相关标准规范分析了消毒供应中心的净化级别;从设计参数、冷热源、空调负荷、空调形式等方面阐述了空调系统的设计;介绍了工作区、清洗设备、高温蒸汽灭菌设备、蒸汽发生器间和低温灭菌间的通风设计要点。
Combined with relevant standards and specifications, the purification level of the disinfection supply center is analyzed;the design of the air-conditioning system is expounded from the aspects of design parameters, cold and heat sources, air-conditioning load and air-conditioning form;and ventilation design points of the work area, cleaning equipment, high-temperature steam sterilization equipment, the steam generator room and the low temperature sterilization room are introduced.
出处
《中国医院建筑与装备》
2022年第6期43-46,共4页
Chinese Hospital Architecture & Equipment
关键词
消毒供应中心
空气净化
空调冷负荷
通风设计
Disinfection supply center
Air purification
Air conditioning cooling load
Ventilation design