期刊文献+

某兆瓦级氢能综合利用站消防水系统设计 被引量:1

Design of fire water system for a MW hydrogen energy comprehensive utilization station
下载PDF
导出
摘要 某兆瓦级氢能综合利用站是国内首个兆瓦级氢能源储能电站,无现成规范和可借鉴的现成设计案例。按照消防设计咨询会专家组意见,确定本项目参照GB 50177—2005《氢气站设计规范》、DL 5027—2015《电力设备典型消防规程》、GB 51048—2014《电化学储能电站设计规范》、GB 50016—2014《建筑设计防火规范》(2018年版)等现行消防规范规程进行设计、施工图审查。根据该项目火灾特点介绍了消防系统选型及设计参数的选取,阐述了选择消防灭火系统扑灭本项目火灾的有效性。 A MW hydrogen energy comprehensive utilization station is the first MW hydrogen energy storage power station in China,no ready-made specifications or design cases for reference.According to the suggestion of the expert group of the fire protection design consultation meeting,the project was designed and the construction drawings were investigated by reference to GB 50177—2005 Design code for hydrogen station,DL 5027—2015 Typical extinguishing and protection regulation of electrical equipment,GB 51048—2014 Design code for electrochemical energy storage station,and GB 50016—2014 Code for fire protection design of buildings(2018 edition).According to the fire characteristics of the said project,the selection of fire extinguishing system and design parameters were introduced,the effectiveness of the selected fire extinguishing system for the said project were elaborated.
作者 毕丽敏 BI Limin(Anhui Provincial Architectural Design and Research Institute Co.,Ltd.,Hefei 230092,China)
出处 《工业用水与废水》 CAS 2022年第3期77-80,共4页 Industrial Water & Wastewater
关键词 纯水电解制氢装置 燃料电池电堆组 空气供应系统 高压氢气储罐区消防水设计 hydrogen production equipment by pure water electrolysis fuel cell unit air supply system fire-fighting water design for high-pressure hydrogen storage tank area
  • 相关文献

同被引文献18

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部