摘要 本文以深圳某办公建筑为例,采用airpak软件对室内热环境进行了多工况的数值模拟对比分析,以室内温度作为主要控制目标对中庭的室内热环境提出优化建议。研究成果结合高大中庭的自身特点,可为夏热冬暖地区的高大中庭的室内空调优化方案提供参考依据。 Taking an office building in Shenzhen as an example, the indoor thermal environment is simulated and analyzed by airpak software under multiple working conditions, and the indoor temperature is taken as the main control target to put forward optimization suggestions for the indoor thermal environment of the atrium. The research results combined with the characteristics of tall atrium can provide reference for the indoor air conditioning optimization scheme of tall atrium in hot summer and warm winter areas.
作者 张艳芳 滕跃亚 崔维玮 康宁 Zhang Yanfang;Teng Yueya;Cui Weiwei;Kang Ning(Tianjin Institute of China Academy of Building Research,Tianjin,300384)
出处 《建设科技》 2022年第11期49-53,共5页 Construction Science and Technology
关键词 高大中庭 数值模拟 空调优化 热环境 tall atrium numerical simulation air conditioning optimization thermal environment