期刊文献+

3.0 T MR多回波Dixon技术与单体素Histo技术肝脏脂肪定量分析 被引量:2

3.0T MR multi-echo Dixon technology and monomer Histo technology fat quantitative analysis study
下载PDF
导出
摘要 目的:探讨SIEMENS3.0TMR多回波Dixon技术与单体素Histo技术对于肝脏脂肪定量分析的可行性。方法:选择20例经临床确诊为脂肪肝的患者,均进行3.0T MR多回波水脂分离Dixon技术和Histo技术检查,Dixon技术所测得序列通过设备自带软件分析得到脂肪分数图,将其和Histo技术所得脂肪分数波谱进行分析,同时进行上腹部CT扫描测量肝脾CT值并计算比值。结果:肝脏穿刺病理组织活检脂肪肝分级与基于MRS的Histo技术获得氢质子密度脂肪分数值及基于Dixon技术的氢质子密度脂肪分数值,两两比较呈正相关性(P<0.05),组间差异均有统计学意义。肝/脾CT值比值与肝脏穿刺病理组织活检脂肪肝分级进行相关性分析,在肝脂肪变性及轻度脂肪肝两组间差异无统计学意义(P>0.05),在中度及重度脂肪肝组之间差异有统计学意义(P<0.05)。结论:3.0T MR多回波Dixon技术与单体素Histo技术定量评估肝脏的脂肪含量是可行的,经3.0T MR多回波Dixon技术和Histo技术检查直接测得肝脏脂肪定量值肝脾CT值比值之间存在一致性,对脂肪肝早期诊断、病情评估和疗效评测具有重要意义。
作者 左亚娜 吴玉辉 郭晟 贺彩虹 Zuo Yana;Wu Yuhui;Guo Sheng;He Caihong
出处 《甘肃医药》 2022年第5期431-433,共3页 Gansu Medical Journal
  • 相关文献

参考文献4

二级参考文献18

  • 1Joe E, Kim SH, Lee KB, et al. Feasibility and accuracy of dual- source dual-energy CT for noninvasive determination of hepatic iron accumulation[ J]. Radiology, 2012, 262: 126-135.
  • 2Fischer MA, Reiner CS, Raptis D, et al. Quantification of liver iron content with CT-added value of dual-energy [ J]. Eur Radiol, 2011, 21 : 1727-1732.
  • 3Johnson TR. Dual-energy CT: general principles [ J ]. A JR Am J Roentgenol, 2012, 199: S3-S8.
  • 4Wang R, Yu W, Wu R, et al. Improved image quality in dual- energy abdominal CT: comparison of iterative reconstruction in image space and filtered back projection reconstruction [ J ]. AJR Am J Roentgenol, 2012, 199 : 402-406.
  • 5Milic S,Stimac D.Nonalcoholic fatty liver disease/steatohepatitis:epidemiology,pathogenesis,clinical presentation and treatment[J].Dig Dis,2012,30(2):158-162.
  • 6Yilmaz Y.NAFLD in the absence of metabolic syndrome:differentepidemiology,pathogenetic mechanisms,risk factors for diseaseprogression[J].Semin Liver Dis?2012,32(l):14-21.
  • 7Bashir MR,Merkle EM,Smithet AD,et al.Hepatic MR imagingfor in vivo differentiation of steatosis,iron deposition and com-bined storage disorder:single-ratio in/opposed phase analysis vsdual-ratio Dixon discrimination [J].Eur J Radiol,2012,81(2):101-109.
  • 8Joe E,Lee JM,Kimet KW,et al.Quantification of hepatic mac-rosteatosis in living,related liver donors using Ti-independent,T2 *-corrected chemical shift MRI [J].J Magn Reson Imaging,2012,36(5):1124-1130.
  • 9彭新桂,居胜红,方芳,滕皋军.化学位移成像及MR波谱分析在体外水脂模型中对脂肪定量的研究[J].中华放射学杂志,2010,44(7):747-752. 被引量:6
  • 10李云卿,祁吉,杨子权,张文波,刘继生,郭得安,刘铁.双能CT检测肺内孤立性结节钙化的价值[J].中华放射学杂志,1999,33(6):374-377. 被引量:7