期刊文献+

一种变电站外来接地线防误管控措施 被引量:2

A Error Prevention Measure for Managing External Grounding Wires in Substations
下载PDF
导出
摘要 介绍了一种变电站外来接地线管理方案,该方案适用于基于运维中心集中放置接地线管理模式下,接地线从运维中心借出到变电站挂拆使用全过程的防误安全管控。将变电站外来接地线纳入站端微机防误系统统一防误管控,有效防止外来接地线随意使用、管理不规范、去向不明确等问题。 A scheme for managing external grounding wires in substations is introduced.The scheme is applicable to the error prevention safety control of the whole process from the borrowing of grounding wire from the operation and maintenance center to the hanging and dismantling of substation under the management mode of centralized placement of grounding wire in the operation and maintenance center.The external grounding wire of the substation is connected to the microcomputer error prevention system at the station end for unified error prevention control,so as to effectively prevent the arbitrary use,non-standard management,unclear destination and other problems of the external grounding wire.
作者 陈念祖 CHEN Nianzu(Zhuhai Unitech Power Technology Co.,Ltd.,Zhuhai 519000,China)
出处 《电工技术》 2022年第6期156-158,共3页 Electric Engineering
关键词 运维中心 公用接地线 外来接地线 operation and maintenance center public grounding wire external grounding wire
  • 相关文献

参考文献3

二级参考文献21

共引文献25

同被引文献8

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部