摘要
介绍了换流变压器绕组温度测量的原理,设计了一种基于突变量的绕组温度告警系统,分析了四种绕组温度测量系统典型故障,并提出了故障处理措施。
The principle of winding temperature measurement of converter transformer is introduced.A winding temperature alarm system based on sudden variable is designed.The typical faults of four winding temperature measurement systems are analyzed,and the treatment and improvement measures are put forward.
作者
叶俊
胡辉祥
熊双成
颜志敏
YE Jun;HU Huixiang;XIONG Shuangcheng;YAN Zhimin(Guangzhou Bareau of EHV Power Transmission Company,CSG,Guangzhou 510663,China)
出处
《电工技术》
2022年第9期109-111,共3页
Electric Engineering
关键词
变压器
绕组温度
CT二次侧开路
绕组温度告警
transformer
winding temperature
CT secondary open circuit
alarm for winding temperature