某船变频器在航行过程中出现故障跳闸导致该船失去动力。根据故障现象、信息、损坏元件进行故障树分析,找到解决方案,排除了故障,恢复了动力。
The fault trip of a ship frequency converter in the navigation process causes the ship to lose power.According to the fault phenomenon,information and damaged components,the solutions are obtained,the fault is eliminated,and the power is restored.