摘要
介绍了1000MW机组超超临界锅炉低温再热器泄漏的事件概况,通过事件多方面原因,得出该次事件的直接原因与间接原因,通过暴露的问题提出一系列的具体防范措施,杜绝同类事件的发生,保障发电企业更好的安全稳定运行。
This paper introduces the general situation of the leakage of the low-temperature reheater of the ultra-supercritical boiler of 1000MW unit.Through various reasons for the incident,the direct and indirect causes of the incident are obtained,and a series of specific preventive measures are proposed through the exposed problems to prevent similar incidents.occurrence,to ensure better safe and stable operation of power generation enterprises.
作者
李文盛
Li Wensheng(Guangdong Datang International Chaozhou Power Generation Co.,Ltd.,Chaozhou 515723,China)
出处
《科学技术创新》
2022年第19期52-55,共4页
Scientific and Technological Innovation