摘要
介绍了厂用电慢切装置在华龙一号核电厂的应用,主要分析了MFC2000-5S电源切换装置的切换方式,从原理上解释了快速切换等切换方式,与普通火电厂用电源切换系统进行对比,指出MFC2000-5S型电源切换装置的优越性,对后续电源切换分析具有借鉴意义。
The application of plant power slow switching device of in HPR1000 nuclear power plant is introduced. The switching mode of MFC2000-5 S power switching device is analyzed. The switching mode such as fast switching from the principle is introduced. Compared with the power switching system used in ordinary thermal power plants, the advantages of MFC2000-5 S power switching device are pointed out, which can be used as a reference for the subsequent power switching analysis.
作者
王晓琳
曹祖庭
杨琦
费兴伟
WANG Xiaolin;CAO Zuting;YANG Qi;FEI Xingwei(CNNC Nuclear Power Operations Management Co.,Ltd.,Jiaxing 314300,China)
出处
《电工技术》
2022年第10期112-113,184,共3页
Electric Engineering
关键词
华龙一号
快速切换
厂用电
HPR1000
fast switching
station service