摘要 在自配抗氧剂测定溶液体系(丙酮/水(V/V)为10:1,高氯酸锂浓度为0.1 mol/L)下,使用Ruler仪器与Autolab电化学工作站PGSTAT101仪器,对含有不同比例抗氧剂的模拟油样进行抗氧剂含量测定。结果表明自配溶液体系用于伏安法测定抗氧剂含量具有可行性,为替代Fluitec公司绿色瓶试剂提供理论依据。 In the self-prepared antioxidant determination solution system(acetone/water(V/V)was 10:1,lithium perchlorate concentration was 0.1 mol/L),Ruler instrument and Autolab electrochemical workstation PGSTAT101 instrument were used to determine the content of simulated oil samples with different proportions of antioxidants were tested for antioxidant content.The results showed that the self-prepared solution system was feasible for voltammetric determination of antioxidant content,which provided a theoretical basis for replacing Fluitec s green bottle reagents.
作者 鄢豪 管亮 左秀丽 谷科城 段纪淼 刘君玉 林科宇 王建 舒建华 YAN Hao;GUAN Liang;ZUO Xiu-li;GU Ke-cheng;DUAN Ji-miao;LIU Jun-yu;LIN Ke-yu;WANG Jian;SHU Jian-hua(Army Logistics Academy,Chongqing 401331,China)
出处 《广州化工》 CAS 2022年第12期106-109,共4页 GuangZhou Chemical Industry
基金 陆军勤务学院2020年青年基金(LQ-QN-202015) 2020年重庆市自然科学基金面上项目(CSTC2020JCYJ-MSXMM0274)。
关键词 伏安法 抗氧剂 RULER PGSTAT101 voltammetry antioxidant Ruler PGSTAT101