期刊文献+

Analysis on Lightning Strike Cause of Directly Buried Optical Cable in Wind Farm and Its Prevention Methods 被引量:3

下载PDF
导出
摘要 Directly buried metal optical cable is a form of erecting optical fiber ring network communication system in wind farms. Although the directly buried optical cable is much less than the overhead optical cable affected by lightning, sometimes lightning damaging optical cable and flashover discharge accidents of optical cable port occurred. In this paper, the amplitude spectrum of lightning wave, the breakdown depth and breakdown distance of lightning wave to soil, the metal components of optical cable port and the impedance characteristics of grounding wire are systematically analyzed, and the prevention methods of directly buried optical cable in wind farm to avoid lightning damage are proposed.
出处 《Meteorological and Environmental Research》 CAS 2022年第3期67-70,共4页 气象与环境研究(英文版)
基金 Supported by Regional Lightning Protection Engineering Technology Research and Development Project in Guangdong Yuedian Dianbai Wind Farm (GDW-PK-21022 Phase II)。
  • 相关文献

参考文献3

二级参考文献28

  • 1罗仕乾.雷电波的频谱及能量分布[J].高电压技术,1995,21(1):85-86. 被引量:37
  • 2Global wind energy market report[DB/OL].2002.3.http://www.awea.org/pubs/documents/GlobalWEMarket2002.pdf
  • 3Wind turbine operation: causes for failure[DB/OL]. http://euwinet.iset.uni-kassel.de.
  • 4Expert group study on recommended practices for wind turbine texting and evaluation: lightning protection for wind turbine installations[DB/OL]. http://www.nrel.gov/wind/lightning/coveriea97.htm.
  • 5Soerensen T, Brask M H. Lightning protection of wind turbines[A].Contributions from the Department of Wind Energy and Atmospheric Physics to EWEC'99 in NICE[C], France, March 1999: 229-232.
  • 6IEC 1024-1, 1990-03: Lightning protection of structures. Part 1:General principles[R].
  • 7Hatziargyriou N M, Lorentzou M I, Cotton I. Transferred overvoltages by windfarm grounding systems[A] , The 8th International Conference on Harmonic and Quafity of Power,ICHQP'98[C], Jointly Organized by IEEE/PES and NTUA,Athens, Greece, October l4-16, 1998: 342-347.
  • 8Hatziargyriou N , Lorentzou M , Cotton I.Wind farm earthing[A]. 1997 the Institution of Electrical Engineers, Printed and Published by the IEE[C], Savoy Place, London WC2R 0BL, UK:1-6.
  • 9Aguado M, Hermoso B, Cid P Met al. Risks assessment for lightning strokes in wind farm installation[A].High Voltage Engineering Symposium[C],22-27 August 1999 Conference Publication,No467,IEE,1999:357-360
  • 10Sakis A P. Meliopoulos, fightning: safety and protection[A], 1997 the institution of electrical engineers, printed and pubfished by the IEE[C], Savoy Place, London WC2R 0BL, UK: 1-7.