对某电站锅炉空间受限区域的小径管进行相控阵超声检测和射线检测,并对检测结果进行对比分析。分析结果表明,相控阵超声检测对坡口未熔合缺陷的检出率明显高于射线检测的检出率,可以有效提升焊接质量,避免缺陷漏检带来的危害。
Phased array ultrasonic testing and radiographic testing were carried out on small diameter tubes in the confined space of a power plant boiler, and the test results were compared and analyzed. It was shown that the detection rate of incomplete fusion defects in groove by phased array ultrasonic testing was significantly higher than that by radiographic testing, which may effectively improve the welding quality and avoid the hazards caused by defect omission.
作者
苏宣机
吴林军
SU Xuanji;WU Linjun(Fujian Boiler and Pressure Vessel Inspection Institute,Fuzhou 350008,China)
出处
《无损检测》
CAS
2022年第3期68-70,共3页
Nondestructive Testing
基金
福建省质量技术监督局科技项目(FJMS2020017)。
关键词
小径管
射线检测
相控阵
未熔合
small diameter pipe
radiographic testing
phased array
imcomplete fusion