期刊文献+

Comparison via Digital Radiography of Radiopacity Levels of Composite Materials with Various Shades and Viscosities

下载PDF
导出
摘要 Aim of the present in vitro study is to evaluate the radiopacity levels of composite resins with various shades and viscosity.10 mm×2 mm discs were prepared from 7 condensable and 4 flowable composites(n=10).An aluminum step wedge ranging from 2.0 to 10.0 mm in thickness was placed on the occlusal film.Digital radiographs were taken using a dental X-ray device and radiographic densities of each step of the aluminum wedge and the samples were recorded to the computer.Five readings were taken and means were calculated.One-Way Anova and Tamhane post hoc tests were performed.While G-eanial Posterior has the highest radiopacity value followed by Filtek Z550,Aelite Flo has the lowest radiopacity value.Posterior composites show higher radiopacity and flowable composites with higher filler loadings have superior radiopacity levels to condensable composites.Enamel and body shades of the composite brands have also statistically significant differences in radiopacity scores.Eventually,radiopacity level of a composite resin material is not affected by the size of fillers;however,the composition,shape and loading of the fillers can specify the radiodensity.
出处 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2022年第2期170-176,共7页 武汉理工大学学报(材料科学英文版)
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部