本文依据JJG 891-2019《电容法和电阻法谷物水分测定仪检定规程》,对电阻法水分测定仪进行了示值误差的测量,分析了误差来源与影响因素,并进行了不确定度评定。
Based on JJG 891-2019"V.R.of Capacitive and Resistive Grain Moisture Testers",the indication error of resistive grain moisture testers was measured,while the source and influence factors were analyzed,and measurement result uncertainty was evaluated.