期刊文献+

基于PLC的供水管网漏水检测系统设计与应用 被引量:5

Design and Application of Water Leakage Detection System of Water Supply Pipe Network Based on PLC
下载PDF
导出
摘要 本文以某卷烟厂供水管道漏水现象为模型,选取一天用水最稳定的时段的用水量最大值为基准值,利用PLC设计控制程序统计每天的用水量与基准值进行对比,当发生漏水时监控系统会显示“管网漏水,请检修!”。此检测系统实施后有效的减少了漏水发现时间,有效减少水资源浪费,保证水压稳定。 This paper takes the leakage phenomenon of water supply pipes of a cigarette factory as the model,selects the maximum water consumption in the most stable period of one day as the reference value,uses the PLC design control program to compare the daily water consumption with the reference value,and monitors the system when water leakage occurs It will display"The pipe network is leaking,please overhaul!".After the detection system is implemented,it effectively reduces the time of water leakage discovery,effectively reduces the waste of water resources,and ensures the stability of water pressure.
作者 陈晴 胡海龙 CHEN Qing;HU Hai-long(Fuyang Cigarette Factory of China Tobacco Anhui Industrial Co.,Ltd.,Fuyang 236000 China)
出处 《自动化技术与应用》 2022年第7期77-79,共3页 Techniques of Automation and Applications
关键词 供水管网 PLC控制 漏水检测 自动报警 water supply network PLC control water leak detection automatic alarm
  • 相关文献

参考文献6

二级参考文献40

  • 1蒋峰,范瑾初,李景华.给水管道检漏工作的新发展[J].化工给排水设计,1994(1):39-43. 被引量:8
  • 2李永刚.多探头相关仪的特点与应用[J].中国给水排水,2007,23(2):106-108. 被引量:9
  • 3徐统涛.浅析漏水管道漏损及检测[J].地下管线管理,2001,(3):53-54.
  • 4[6]常贵林,刘吉东.工业泄漏与治理[M].北京:中国石化出版社,2001.
  • 5刘淑媛.谈地下管网测漏中水平衡探测[J].地下管线管理,1996,(2):54.
  • 6张文智.浅论流量测定在漏水调查中的应用[J].地下管线管理,1997,(1):35.
  • 7陈海生,谢广省.给水管网"升压检漏"法[J].地下管线管理,1999,(1):35-36.
  • 8孙立国,郝英杰.氢气示踪法在检验新建管道中的应用[J].地下管线管理,2001,(6):53-55.
  • 9王继明,杨昌彬.浅谈漏水听音原理及在实践中的应用[J].地下管线管理,2002,(3):38-39.
  • 10孙玉晶.浅谈声波检漏术[J].地下管线管理,1997,(1):36.

共引文献38

同被引文献20

引证文献5

二级引证文献4