摘要
油浸式主变压器是核电厂运行系统重要部件之一,其结构复杂,储油量多、风险系数高,是核电厂火灾报警系统重点监控设备。通过分析油浸式变压器火灾产生原因、风险及事故特征,提出了核电厂油浸式变压器火灾预防措施以及对应的火警响应与扑救对策。
Oil-immersed main transformer is one of the important components of a nuclear power plant operation system.It has a complex structure,a large oil storage capacity and a high risk factor.It is the key monitoring equipment of the nuclear power plant fire alarm system.By analyzing the causes,risks and accident characteristics of oil-immersed transformer fires,the fire prevention measures of oil-immersed transformers of nuclear power plants are proposed as well as the corresponding fire response and fire fighting countermeasures are proposed.
作者
窦元梁
孙宝承
DOU Yuanliang;SUN Baocheng(DCNNP Xiapu Nuclear Power Co.,Ltd.,Ningde 355100;Suzhou Nuclear Power Research Institute Co.,Ltd.,Suzhou 215004)
出处
《电力安全技术》
2022年第6期66-69,共4页
Electric Safety Technology
关键词
核电厂
油浸式变压器
火灾预防
响应与扑救
nuclear power plant
oil-immersed transformer
fire prevention
response and fighting