期刊文献+

某冷冻库电热融霜和热气融霜功耗对比分析 被引量:3

Comparative analysis of power consumption of electric defrosting and hot vapor defrosting in a frozen storage
下载PDF
导出
摘要 通过分析制冷和融霜运行流程,对3个工况下某冷冻库的电热融霜和热气融霜功耗进行对比分析。结果表明,热气融霜是较为节能的融霜方式,其融霜功耗降低20%以上,制冷系统运行功耗降低12%以上。 By analyzing the operation process of refrigeration and defrosting,the power consumption of electric defrosting and hot vapor defrosting in a frozen storage is compared under three working conditions.The results show that the hot vapor defrosting is more energy-saving,its defrosting power consumption is reduced by above 20%,and the opera-tion power consumption of refrigeration system is reduced by above 12%.
作者 陈建平 黄劲松 史雪菲 牛新朝 吴迪 Chen Jianping;Huang Jinsong;Shi Xuefei;Niu Xinchao;Wu Di(Chinese Academy of Agricultural Mechanization Sciences Group Co.,Ltd.;Sinomach Tdi International Engineering Co.Ltd.)
出处 《制冷与空调》 2022年第6期101-104,109,共5页 Refrigeration and Air-Conditioning
关键词 冷冻库 电热融霜 热气融霜 直接膨胀供液 frozen storage electric defrosting hot vapor defrosting direct expansion liquid supply