摘要
结合一次ZPW-2000轨道电路连接中断,造成列控中心对信号机驱采不一致引发的报警进行分析。主要对列控中心的设计原理、技术要求进行分析,结合维护终端数据,逐步推导,还原出故障经过,确定故障原因,并提出解决方案。
An alarm is raised by the train control center because of the inconsistency between state acquisition information and driving control information of signals caused by the interruption of communication with ZPW-2000 track circuits.This paper analyzes this alarm by examining the design principles and technical requirements of the train control center,makes inferences and restores the failure process step by step based on the data on the maintenance terminal,determines the cause of the failure,and proposes a solution.
作者
于洋
Yu Yang(Dispatching Department,China Railway Taiyuan Group Co.,Ltd.,Taiyuan 030013,China)
出处
《铁路通信信号工程技术》
2022年第7期112-115,共4页
Railway Signalling & Communication Engineering
关键词
列控中心
驱采不一致
ZPW-2000轨道电路
信号机
TCC
inconsistency between acquisition information and driving information
ZPW-2000 track circuit
signal