摘要 送风机设计选型裕量偏大,运行中入口导叶开度小,运行效率点偏离性能高效区,低负荷时调节性能较差。为改善送风机调节性能和提高运行效率,结合实际条件,进行送风机技术改造的可行性研究。综合对比分析了变频调速与永磁调速两种技术路线,最终选定了永磁调速改造方案。 The design and selection margin of forced draft fan is too large,the opening of the inlet guide blade is small during operation,the operating efficiency point deviates from the performance efficiency area,and the regulation performance is poor under low load.In order to improve the regulating performance and operating efficiency of forced draft fan,the feasibility study of technical transformation of forced draft fan is carried out in combination with the actual conditions.The two technical routes of variable frequency speed regulation and permanent magnet speed regulation are comprehensively compared and analyzed,and the transformation scheme of permanent magnet speed regulation is finally selected.
作者 李旭 董达 陈学兵 胡海滨 LI Xu;DONG Da;CHEN Xuebing;HU Haibin(Huaneng Anyang Thermal Power Co.,Ltd.,Anyang 455000,China;China Huaneng Group Co.,Ltd.,Beijing 100000,China)
出处 《黑龙江电力》 CAS 2022年第3期267-270,共4页 Heilongjiang Electric Power
关键词 送风机 变频调速 永磁调速 节能改造 forced draft fan variable frequency speed regulation permanent magnet speed regulation energy saving reconstruction