摘要
介绍了某轮一机多库伙食冷藏系统的工作原理,通过观察记录该系统的工作数据,发现压缩机存在启停频繁的问题,分析了产生问题的原因,提出了适当升高库温、适当增大温差和设计更合理的PLC程序三种解决方案。
The working principle of a ship's multi-store meal refrigeration system was introduced.By observing and recording the working data of the system,it was found that the compressor had the problem of frequent starting and stopping,and the reasons for the problem were analyzed,and three solutions were proposed,namely,to raise the temperature of the store appropriately,to increase the temperature difference appropriately and to design a more reasonable PLC program.
作者
吴海春
Wu Haichun(Bohai Shipbuilding Vocational College,Xingcheng Liaoning 125105)
出处
《现代工业经济和信息化》
2022年第6期323-325,共3页
Modern Industrial Economy and Informationization
关键词
伙食冷藏系统
启停频繁
解决方案
food refrigeration system
frequent starting and stopping
solution