期刊文献+

武汉某写字楼地源热泵系统设计与实施

Design and Implementation of Ground-source Heat Pump System in an Office Building in Wuhan
下载PDF
导出
摘要 以武汉某写字楼地源热泵系统为例,对系统实施与设计的差异、施工阶段出现的主要问题进行了分析和总结,对地源热泵系统设计和施工中三类常见问题给出了相应的实施建议。 Taking the ground-source heat pump system of an office building in Wuhan as an example,the differences between system implementation and design and the main problems in the construction stage are analyzed and summarized,and the corresponding implementation suggestions are given for three common problems in the design and construction of ground-source heat pump system.
作者 胡先芳 周敏锐 雷建平 陈焰华 HU Xian-fang;ZHOU Min-rui;LEI Jian-ping;CHEN Yan-hua(CITIC General Institute of Architectural Design and Research Co.,Ltd.)
出处 《建筑热能通风空调》 2022年第6期58-60,39,共4页 Building Energy & Environment
关键词 地源热泵 交叉施工 水力平衡 Ground-source heat pump Cross construction Hydraulic balance