期刊文献+

消声室中垂直反射面对噪声测试结果的影响研究

Study on the Influence of Vertical Reflecting Plane on Noise Test Results in Anechoic Chamber
下载PDF
导出
摘要 按照相关噪声测试标准,一些家电产品需考虑实际使用情况,采用靠墙的方式来进行噪声声功率结果的测试。该方法要求在一个加装垂直反射面的半消声室内完成。本文通过理论分析和实验验证,研究六点靠墙法与十点半球法之间的理论误差,以及不同的垂直反射面对其测量结果的影响。 According to the relevant noise test standards,some household electrical appliances need to consider the actual use situation and adopt the method of leaning against the wall to test the noise sound power results.This method is required to be completed in a semi anechoic room equipped with vertical reflecting plane.Through theoretical analysis and experimental verification,this paper studies the error between the six point wall method and the ten point hemispherical method,and the influence of different vertical reflecting plane on its measurement accuracy.
作者 彭强 李泽超 苏岳 PENG Qiang;LI Ze-chao;SU Yue(China Household Appliances Research Institute;Beijing Institute of Technology)
出处 《中国标准化》 2022年第13期194-197,共4页 China Standardization
关键词 声功率级 垂直反射面 吸声系数 噪声测试 sound power level vertical reflecting plane sound absorption coefficients noise test
  • 相关文献

参考文献1

二级参考文献2

  • 1Acoustics-Determination of sound absorption coefficient and impedance in impedance tubes-Part 2 Transfer-fcunction method( ISO 10534 - 2), 1998.
  • 2Krueger J., Quickert M. Determination of acoustic absorber parameters in impedance tubes. Applied Acoustics[J]. 1997,50(1) :79 - 89.

共引文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;