期刊文献+

无体位改变的导航辅助侧方腰椎间融合术

Navigation assisted lateral lumbar interbody fusion in the unchanged lateral position
原文传递
导出
摘要 [目的]介绍无体位改变导航辅助侧方腰椎间融合术的手术技术和初步临床效果。[方法]2017年10月—2019年5月,采用无体位改变导航辅助侧方腰椎间融合术治疗退变性腰椎滑脱症患者27例。取右侧卧位,首先完成侧方入路椎间盘切除及融合器置入。然后,不改变体位,将导航参考架固定于左侧髂嵴,O形臂X线机扫描获取手术节段三维图像并传输至导航主机,在导航实时引导下完成经皮椎弓根钉-棒固定。[结果]所有患者均顺利完成手术,无严重并发症。27例患者共置入椎弓根螺钉122枚,平均置钉时间(9.22±3.84)min/枚;按照Gertzbein-Robbins分级标准,置钉准确率为93.44%。所有患者均获随访3~24个月,末次随访时腰痛、腿痛VAS评分和ODI评分、术后滑脱率、椎间隙高度和硬膜囊面积均较术前显著改善(P<0.05)。按改良MacNab标准临床效果优良率100%。[结论]无体位改变导航辅助侧方腰椎间融合术是一种安全高效的手术方法。 [Objective]To introduce the surgical technique and primary clinical outcomes of navigation assisted lateral lumbar interbody fusion in the unchanged lateral position.[Methods]From October 2017 to May 2019,27 patients underwent abovementioned surgical procedures for degenerative lumbar spondylolisthesis.As the patients were placed in right lateral position,discectomy and cage implantation of the involved disc were firstly conducted though a small incision on the left side.Subsequently,maintaining the position unchanged,the navigation reference fixed on the left iliac crest and the segmental three-dimensions images were obtained by O-arm fluoroscopy and transferred to navigator.Finally,percutaneous pedicle screw-rod placement was performed under real-time navigation guidance.[Results]All the 27 patients had operation performed smoothly without serious complications.A total 122 pedicle screws were placed in the 27 patients with an average screw placement time of(9.22±3.84)min/screw and accuracy of pedicle screw placement of 93.4%based on Gertzbein-Robbins criteria.At the latest follow-up ranged from 3 to 24 months,the ODI and VAS scores for low back pain and leg pain,as well as the slippage rate,intervertebral space height and cross-sectional of the dural sac measured on radiographs significantly improved compared with those preoperatively(P<0.05).According to MacNab’s criteria,the excellent and good rate of clinical outcome was 100%.[Conclusion]This navigation assisted lateral lumbar interbody fusion in the unchanged lateral position is a safe and high-efficient surgical technique.
作者 文浩辉 刘赫 王敏 杨大志 易伟宏 WEN Hao-hui;LIU He;WANG Min;YANG Da-zhi;YI Wei-hong(Department of Spine Surgery,Union Shenzhen Hospital,Huazhong University of Science and Technology,Shenzhen 518052,China)
出处 《中国矫形外科杂志》 CAS CSCD 北大核心 2022年第12期1115-1118,共4页 Orthopedic Journal of China
关键词 腰椎侧方融合 导航 同一体位 经皮椎弓根钉-棒固定 lateral lumbar interbody fusion navigation single position percutaneous pedicle screw placement
  • 相关文献

参考文献5

二级参考文献44

  • 1刘亚军,田伟,刘波,李勤,胡临,李志宇,袁强,孙玉珍.CT三维导航系统辅助颈椎椎弓根螺钉内固定技术的临床应用[J].中华创伤骨科杂志,2005,7(7):630-633. 被引量:44
  • 2田伟,刘亚军,刘波,李勤,胡临,李志宇,袁强.计算机导航在脊柱外科手术应用实验和临床研究[J].中华骨科杂志,2006,26(10):671-675. 被引量:48
  • 3Kotani Y, Cunningham BW, Abmni K, et al. Biomechanieal analysis of cervical stabilization systems: an assessment of transpedicular screw fixation in the cervical spine [J]. Spine, 1994, 19(22): 2529-2539.
  • 4Ito Z, Higashin~ K, Kato S, et al. Pedicle screws can be 4 times stronger than lateral mass screws for insertion in the midcervical spine: a biomechanical study on strength of fixa- tion[J]. J Spinal Disord Teeh, 2012, 27(2): 80-85.
  • 5Cacciola F, Phalke U, Goel A. Vertebral atery in relationship to C1-C2 vertebrae: an anatomical study [J]. Neurol India, 2004, 52(2): 178-184.
  • 6Ishikawa Y, Kanemura T, Yoshida G, et al. Intraoperative, full-rotation, three-dimensional image(o-arm)-based navigation system for cervical pedicle scl~w insertion [J]. J Neurosurg Spine, 2011, 15(5): 472-478.
  • 7Neo M, Sakamoto T, Fujibayashi S, et al. The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae[J]. Spine, 2005, 30(24): 2800-2805.
  • 8Oda I, Abumi K, Sell LC, et al. Biomechanical evaluation of five different occipito-atlanto-axial fixation techniques [J]. Spine, 1999, 24(22): 2377-2382.
  • 9Mueller CA, Roesseler L, Podlogar M, et al. Accuracy and complications of transpedieular C2 screw placement withoutthe use of spinal navigation[J]. Eur Spine J, 2010, 19(5): 809-814.
  • 10Wright NM, Lauryssen C. Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves[J]. J Neurosurg, 1998, 88(4): 634-640.

共引文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部