摘要
通过火烧试验、水压爆破试验和热分析等手段,研究典型火烧工况下储氢装置的热响应行为、损伤形态及碳纤维复合材料微细观损伤特征。结果表明,在规定火烧条件下储氢装置平均失效压力为41.5 MPa,比常温环境下(35 MPa-166 L水爆压力125.5 MPa)降低约67%;环氧树脂热分解发生在100~600℃,并表现出4个明显的阶段性反应特征;碳纤维热分解主要发生在600~950℃,在849℃时失重速率最快为0.87%/℃;火灾场景下高压储氢装置可能出现火烧损伤、爆炸损伤和热辐射损伤3种典型热损伤模式,其中爆炸场景下碳纤维残余物丝体呈多处层状脆性破碎,具有明显的力学损伤特征。
In this paper,the thermal response behaviors,damage morphology,and microscopic damage characteristics of typeⅢhydrogen tanks were studied under typical fire conditions.These properties were investigated by methods of bonfire test,hydraulic burst test,and thermal analysis.Results show that the hydraulic burst pressure of typeⅢtank(35 MPa-166 L)is 125.5 MPa.However,the average failure pressure of the tanks under the prescribed fire conditions is 41.5 MPa,which is reduced by about 3 times in the fire environment.The decomposition of epoxy resin occurs in temperature range of 100 to 600°C,which exhibits four obvious phases of reaction.The decomposition of carbon fiber mainly occurs in temperature range of 600 to 950℃,in which the fastest weight loss rate is 0.87%/℃at 849℃.In addition,three typical thermal damage modes of the high-pressure hydrogen tanks at fire scenarios are discussed,such as fire damage,explosion damage,and thermal radiation damage.The carbon fiber remnant filament at explosion scene showsbrittle broken in layers with obvious mechanical damage characteristics.
作者
李贝
王雪莹
金鑫
李强
韩冰
郭传江
Li Bei;Wang Xueying;Jin Xin;Li Qiang;Han Bing;Guo Chuanjiang(School of Chemical Engineering,Dalian University of Technology,Dalian 116024,China;Dalian Boiler and Pressure Vessel Inspection&Detection Institute Co.,Ltd,Dalian 116012,China;Key Laboratory of Gas Cylinders Safety Technology for State Market Regulation,Dalian 116012,China;Dalian Inspection Testing&Certification Group Co.,Ltd.,Dalian 116013,China)
出处
《太阳能学报》
EI
CAS
CSCD
北大核心
2022年第6期398-404,共7页
Acta Energiae Solaris Sinica
基金
国家重点研发计划(2021YFB4000900)
中央引导地方科技发展专项(2022JH6/100100027)
大连市科技创新项目(2021JJ13SN79)。
关键词
燃料电池
高压储氢
碳纤维
爆炸
火灾场景
fuel cell
high-pressure hydrogen storage
carbon fiber
explosion
fire scenarios