螯合树脂塔的正常运行和维护是螯合树脂塔提供高质量精盐水的基础,是离子膜电解槽能够长期以较高的电流效率和较低的槽电压运行的保证。从运行、维护、定期检查及大检修维护等方面进行了重点分析,确保树脂塔始终处于良好的运行状态。
The normal operation and maintenance of the chelating resin tower is the basis for the chelating resin tower to provide high-quality refined brine,and is the guarantee that the ion-exchange membrane electrolyzer can operate with high current efficiency and low cell voltage for a long time.This paper focuses on the analysis of operation,maintenance,regular inspection and overhaul maintenance,so as to ensure that the resin tower is always in a good running state.
作者
杜元鹏
王宏飞
DU Yuan-peng;WANG Hong-fei(Shaanxi Beiyuan Chemical Group Co.,Ltd.,Yulin 719319,China)
出处
《中国氯碱》
CAS
2022年第7期5-8,共4页
China Chlor-Alkali
关键词
离子膜电解槽
螯合树脂塔
钙镁离子
反洗
ionic membrane electrolyzer
chelating resin tower
calcium and magnesium ions
backwashing