摘要
随着环保及标准规范要求的提高,需要对现有的液氯储存厂房进行封闭改造,通过采用固定墙体加卷帘门的封闭设计,同时辅以优化有毒气体报警仪布置、负压管道设置及水喷淋等设施优化设计,可以避免事故下氯气外漏的风险,达到液氯储存厂房安全运行的效果。
With the improvement of environmental protection and the requirements of standards and specifications,the existing liquid chlorine storage workshop needs to be closed and transformed.By adopting the closed design of fixed wall and rolling shutter door,supplemented by the optimal design of toxic gas alarm,negative pressure system and water spray facilities,the risk of chlorine leakage can be avoided.Achieve the effect of safe operation of liquid chlorine storage workshop.
作者
李庆增
Li Qingzeng(CNOOC Petrochemical Engineering Co.,Ltd.,Jinan 250000,China)
出处
《山东化工》
CAS
2022年第13期167-169,共3页
Shandong Chemical Industry
关键词
液氯储存
泄漏
封闭
负压系统
水喷淋
安全管理
liquid chlorine storage
leakage
closed
negative pressure system
water spray