摘要 [目的]介绍经骨隧道镜下股骨颈断裂克氏针取出的手术技术和初步临床效果。[方法]2011年3月—2020年5月本院骨科共收治股骨颈克氏针断裂7例。影像检查确定断裂克氏针的深度,取出原固定空心钉,用空心环钻沿克氏针向近端延长骨隧道,X线透视下略超过克氏针断端时停止,置入关节镜,直视下寻找断裂的克氏针残余,置入夹持钳,确定夹住针尾后,拔出断裂的克氏针,骨隧道内植骨。[结果]所有患者均顺利完成手术,手术时间(23.30±3.90)min,出血量(16.20±4.40)ml。骨隧道近端与关节面距离(1.80±1.00)cm。末次随访时X线片显示骨隧道植骨区骨愈合,未出现内固定松动或内固定周围骨吸收,也未出现股骨颈骨折。髋关节Harris功能评分(84.40±4.64)分。[结论]经骨隧道关节镜技术应用于股骨颈断裂克氏针取出,具有损伤小、高效的优点,术中无需额外破坏隧道周围骨质,断针取出后可以继续执行内固定计划。 [Objective]To introduce the surgical technique and preliminary outcomes of taking out broken guide wire in femoral neck with intramedullary bone endoscopy.[Methods]Between March 2011 and May 2020,7 patients had broken guide wire in femoral neck removed by intramedullary bone endoscopy in our department.After imaging check to determine the depth of the broken wire,the original fixed cannulated screw was taken out,and the original bone tunnel was enlarged with a cannulated drill,which stopped as just beyond the distal end of the broken wire under X-ray fluoroscopy.As the arthroscope was introduced into the bone tunnel,the broken wire was identified with a small curett.A grasp forceps was introduced into the tunnel to hold the retained wire,and pulled back to take out the broken wire.Finally,bone grafts were inserted into the tunnel.[Results]All patients underwent successful operation with operation time of(23.30±3.90)min,blood loss of(16.20±4.40)ml and the distance between proximal bone tunnel and articular surface of(1.80±1.00)cm.Radiographs at the latest follow-up showed bone union in the bone tunnel graft area with no loosening of fixation or bone resorption around fixation,and no femoral neck fracture.The Harris score was of(84.40±4.64)at the latest follow up.[Conclusion]Removal of broken guide wire in femoral neck with intramedullary bone endoscopy is efficient,and has benefits of minimalizing iatrogenic trauma,no additional damage to the tunnel,and maintaining the original internal fixation.
作者 梁志白 徐谦 吕辉照 艾建国 赵枫 LIANG Zhi-bai;XU Qian;Lü Hui-zhao;AI Jian-guo;ZHAO Feng(The Department of Orthopaedics,the 910^(th)Hospital,Joint Logistic Force of CPLA,Quanzhou 362000,China)
出处 《中国矫形外科杂志》 CAS CSCD 北大核心 2022年第13期1212-1215,共4页 Orthopedic Journal of China
关键词 股骨颈 克氏针断裂 关节镜 骨隧道 femoral neck broken guide wire endoscopy bone tunnel
  • 相关文献

参考文献1

二级参考文献13

  • 1Sharma H, Chauhan M, Maini L. A technique to remove a broken guide wire transfixing the hip joint [J]. Acta Orthop Belg 2008;74(5);683-5.
  • 2Mishra P, Jain P, Aggarwal A, et al. Intrapelvic protrusion of guide wire during fixation of fracture neck femur [J]. Injury 2002;33(9);839- 41.
  • 3Mishra P, Gautam VK. Broken guide wire with intrapelvic protrusion: a technique for removal [J]. Injury 2004;35(12); 1324- 6.
  • 4Buch RG, Kernek CB, Madura JA, et al. lntrapelvic migra- tion of Knowles pin through external iliac vein [J]. Orthopedics 1985;8(8): 1023-4.
  • 5Alpers DD. Migration of broken hip pin into urinary blad- der [J]. JAMA 1970;212(12):2123-4.
  • 6Seitz WH Jr, Berardis JM, Giannaris T, et al. Perforation of the rectum by a Smith-Petersen nail [J]. J Trauma 1982;22(4): 339-40.
  • 7Fong YC, Lin WC, Hsu HC. Intrapelvic migration of a Kirschner wire [J]. J Chin Med Assoc 2005 ;68(2);96-8.
  • 8Sayegh FE, Tintzas D, Kapetanos GA. Intrapelvic migra- tion of a guide pin during fixation of a hip fracture: who and what is to blame [J]? Acta Orthop Belg 2003;71(2):239-41.
  • 9Kottmeier S, Born CT, Saul H. Laparoscopic retrieval of a migrating intrapelvic pin: case report and review of the literature [J]. J Trauma 1993;35(6):952-5.
  • 10Peivani MT, Kachooei AR, Nazemain Z. New method to remove the broken guide pin in the hip joint [J]. Orthopaedics 2011 ;34(10); 685-7.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部