高灵敏ECL-RET传感器的构建及其用于血清前列腺特异性抗原检测的研究 被引量:1

Construction of a Sensitive Electrochemiluminescence Resonance Energy Transfer Biosensor and Its Application in Detection of Prostate Specific Antigen in Serum
下载PDF
导出
摘要 肿瘤标志物在癌症早期诊断与预后监测中具有非常重要意义。前列腺癌作为男性泌尿生殖系统中最常见的恶性肿瘤,其血清前列腺特异性抗原(PSA)是最重要的早期检测指标。该研究以制备的四元Cu-Zn-In-S纳米晶(NCs)作为发光体,金纳米星(AuNSs)作为猝灭探针,利用K2S2O8作为共反应剂,发展了一种基于量子点电化学发光共振能量转移的免疫传感器(ECL-RET)用于血清中PSA的高灵敏检测。固定在传感器上的NCs表现出极强的初始ECL信号和较低的ECL电位。作为固定基底的多壁碳纳米管(MWNTs)不仅加速了NCs与S_(2)O^(2-)_(8)之间的反应,获得了较高的ECL信号,而且作为载体可以固定大量的抗体,提高传感器检测PSA的灵敏度。采用电化学交流阻抗法(EIS)对组装过程进行跟踪,证实了该传感器组装的可行性。采用电化学发光法研究了传感器对底液中不同浓度PSA的响应,结果显示,随着体系中PSA浓度的增加,电极上结合AuNSs的标记抗体(Ab2-AuNSs)越多,触发的猝灭效果越明显,ECL信号降低越明显。因此,该传感器表现出对PSA较好的分析性能,其线性范围为0.01~150 ng/mL,检出限为0.03 ng/mL。用于血清样品的检测,该传感器的测试结果与常用的化学发光法基本吻合,相对误差仅为−7.2%~6.0%,结果准确度良好,为临床检测PSA提供了准确可靠的新方法。 The accurate and rapid quantitative detection on cancer biomarkers is of great significance to early diagnosis and prognosis monitoring,especially for prostate cancer,the most common malignant tumor in male genitourinary system,its prostate specific antigen(PSA)is the most important early detection index for blood serum.Herein,an electrochemiluminescence resonance energy transfer immunosensor(ECL-RET)was constructed for the ultrasensitive detection of PSA in serum,with quaternary Cu-Zn-In-S nanocrystals(NCs)as the ECL donor and gold nanostars(AuNSs)as the acceptor.The immunosensor exhibited a very strong initial ECL signal and a low ECL potential.The multi-walled carbon nanotubes(MWNTs)attached on the substrate not only accelerated the reaction between NCs and S_(2)O^(2-)_(8) to obtain a high ECL signal,but also assembled a large number of antibodies to improve the sensitivity of the sensor as a carrier.The electrochemical impedance spectroscopy(EIS)was used to investigate the assembly process,and electrochemiluminescence(ECL)was used to study the response to different concentrations of PSA.The proposed ECL-RET immunosensor possessed a good analytical performance,with a wide linear range of 0.01-150 ng/mL and a detection limit(S/N=3)of 0.03 ng/mL.In addition,the ECL-RET immunosensor was successfully applied to the determination of PSA in human serum samples,with relative errors of-7.2%-6.0%,indicating that the proposed immunosensor is a promising tool for PSA detection in real samples.
作者 孙莹莹 张佳佳 王丹 王蔚 郭胜男 SUN Ying-ying;ZHANG Jia-jia;WANG Dan;WANG Wei;GUO Sheng-nan(Department of Medical Laboratory Science,Liaoning University of Traditional Chinese Medicine,Shenyang 110847,China)
出处 《分析测试学报》 CAS CSCD 北大核心 2022年第8期1200-1206,共7页 Journal of Instrumental Analysis
基金 辽宁省自然科学基金项目(2021-MS-249) 辽宁省教育厅重点科研项目(LJKZ0888) 辽宁省人社厅百千万人才资助项目(2020921098) 辽宁中医药大学高层次人才科研启动基金。
关键词 电化学发光共振能量转移 前列腺特异性抗原(PSA) 四元纳米晶 多壁碳纳米管(MWNTs) electrochemiluminescence resonance energy transfer(ECL-RET) prostate specific antigen(PSA) quaternary Cu-Zn-In-S nanocrystals multi-walled carbon nanotubes(MWNTs)
  • 相关文献

参考文献1

二级参考文献4

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部