Effect of geometric parameters at open turbine combined structure on flow field distribution of dry granulation for Si_(3)N_(4) powder

原文传递
导出
摘要 To improve the uniformity of the flow field and the poor axial velocity in the chamber of Si3N4 dry granulation, the influence of geometric parameters at open turbinecombined structure on the flow field distribution is studied. The Euler–Euler gas-solidtwo-phase flow model is established and the physical model of dry granulation chamberunder the combined structure is simplified. Under the same radial structure, the volumedistribution and velocity field of Si3N4 particles in the granulation chamber with a different number and angle of the axial structure at the open turbine are analyzed by theCFD method. The influence of the axial structure at the open turbine on the flow fielddistribution of Si3N4 particles under different geometric parameters is compared. Theresults show that the axial structure of the open turbine in the granulation chamber isthe most uniform when the number of blades is 6 and the inclination angle is 45◦, andthe circulating flow of the upper and lower parts of Si3N4 powder is strong.
出处 《International Journal of Modeling, Simulation, and Scientific Computing》 EI 2021年第5期59-77,共19页 建模、仿真和科学计算国际期刊(英文)