期刊文献+

化学发光流动注射法测定雨水中过氧化氢 被引量:8

CHEMILUMINESCENT METHOD FOR THE DETERMINATION OF HYDROGEN PEROXIDE IN RAIN WATER BY FLOW INJECTION ANALYSIS
全文增补中
导出
摘要 用化学发光流动注射分析装置,将16孔阀连接成异步双流路,以过氧化氢-鲁米诺-钴(Ⅱ)为化学发光体系,建立了快速测定雨水中过氧化氢的方法,最低检测限为0.1ng/ml,在0.1—400ppb范围内有良好的线性关系,相对标准差为0.78—3.03%,每小时可分析480个以上的样品. The determination of hydrogen peroxide in rain water by flow injection system with an asynchronous sample valve of two loops using Co(Ⅱ) catalyzed luminol chemiluminescence is presented. The optimum condition is discussed and the effects of interferents could be minimized using KF of 0.1mol/L. The detection limit of the method is 0.1ng/ml H2O2 with a linear response up to 400 ng/ml. The relative standard deviation is 3.03% and sample throughput is 480 samples per hour.
出处 《环境科学学报》 CAS CSSCI CSCD 北大核心 1989年第4期483-487,共5页 Acta Scientiae Circumstantiae
关键词 过氧化氢 雨水 流动注射 化学发光 chemiluminescence flow injection hydrogen peroxide lu-minol Co(II) system.