摘要
为了实现《固定式压力容器安全技术监察规程》中的设计要求,即第Ⅲ类压力容器接管与壳体之间焊接接头应采用全截面焊透结构,对电加热压力容器平盖上电加热棒套管的安装及焊接问题进行分析,提出一种接管的全截面焊透结构设计,该结构采取了不锈钢管冷装工艺,在满足法规的前提下保证了清洁度的设计要求。
In order to comply with the stipulation in“Supervision Regulation on Safety Technology for Stationery Pressure Vessel”,in which the full sectional penetration welding joint between nozzle and shell in classⅢpressure vessels is required,the issue of assembly and welding of drive-pipe for electric heating rod to the flat cover in electric heating pressure vessel was analyzed.One structure of full sectional penetration welding joint for nozzle was presented in this article.Cold installation technology for stainless steel was used for this structure,by which the cleanness required in design was realized and the stipulation in the regulation was satisfied at the same times.
作者
赵彬彬
金东杰
张焱
白新文
浦承皓
Zhao Binbin;Jin Dongjie;Zhang Yan;Bai Xinwen;Pu Chenghao(Chinergy Co.,Ltd,Beijing 100193,China;Nuclear and Radiation Safety Center,Beijing 100082,China)
出处
《化工设备与管道》
CAS
北大核心
2022年第4期19-22,共4页
Process Equipment & Piping
关键词
全截面焊透
结构设计
平盖
冷装工艺
full sectional penetration welding
structural design
flat cover
cold installation technology