摘要 建立超痕量六价铬分析仪快速测定生活源回收塑料中六价铬[Cr(Ⅵ)]含量方法。塑料样品被粉碎后,经浸提、显色、调节pH和蒸馏水定容,上机检测。实验结果表明:六价铬保留时间在80~90 s之间,峰形良好,在3 min内完成分析;在5~50μg/L范围内线性关系良好,相关系数(R)为0.9992,方法检出限为0.08 ng/L,方法加标回收率在95.2%~106.3%之间,相对标准偏差(RSD)为3.2%。使用该方法对10批次生活源回收塑料进行检测,六价铬质量分数在0.105~2.162 mg/kg之间。该法灵敏度高,检出限低,能自动进样分析,不受样品基体影响,能够满足生活源回收塑料中六价铬的检测需求。 An ultra-trace Chromium(Ⅵ)analyzer was established to quickly determine the content of Chromium(Ⅵ)in recycled plastics from life sources.After the plastic sample was crushed,it is extracted,colored,adjusted pH value,and fixed volume with distilled water,and tested on the machine.The experimental results showed that the retention time of Cr(Ⅵ)was between 80 s and 90 s,the peak shape was good,and the analysis was completed within 3 min.The linear relationship was good in the mass concentration range of 5-50μg/L,the correlation coefficient(R)was 0.9992,the detection limit of the method was 0.08 ng/L,the recovery rate was between 95.2%and 106.3%,and the relative standard deviation(RSD)was 3.2%.Using this method,10 batches of recycled plastics from living sources were tested,and the content was between 0.105 mg/kg and 2.162 mg/kg.The method has high sensitivity and low detection limit,it can be automatically injected and analyzed,and is not affected by the sample matrix.The method can meet the detection requirements of Cr(Ⅵ)in recycled plastics.
作者 沈宏林 陈纪文 温福全 霍斯欣 冯艳 刘琼 SHEN Honglin;CHEN Jiwen;WEN Fuquan;HUO Sixin;FENG Yan;LIU Qiong
出处 《上海化工》 CAS 2022年第4期62-65,共4页 Shanghai Chemical Industry
基金 国家重点研发计划项目——“国家质量基础的共性技术研究与应用”重点专项(2019YFF0216900,2019YFF0216901,2019YFF0216903)。
关键词 六价铬 超痕量分析 生活源回收塑料 Chromium(Ⅵ) Ultra-trace analysis Life source recycled plastics
  • 相关文献

参考文献8

二级参考文献103

共引文献139

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部