期刊文献+

超声引导下细针穿刺抽吸甲状腺结节标本质量的影响因素 被引量:6

Impact factors of quality of ultrasound-guided fine needle aspiration specimens of thyroid nodules
下载PDF
导出
摘要 目的观察超声引导下细针穿刺抽吸(US-FNA)甲状腺结节标本质量的影响因素。方法选取388例接受US-FNA的甲状腺结节患者(共436个结节),根据标本背景的血液成分、细胞数目、存留组织框架及细胞破坏程度将其分为诊断优越组(n=325)和非诊断优越组(n=111),比较其超声特征,主要包括结节最大径、形态、边界、回声、钙化及血供,分析影响US-FNA标本质量的因素。结果组间甲状腺结节最大径、内部钙化及Adler血供差异均有统计学意义(P均<0.05)。甲状腺结节最大径及钙化为US-FNA标本质量的影响因素(P=0.010、0.002)。结论超声所见甲状腺结节最大径及钙化为其US-FNA标本质量的影响因素。 Objective To explore the impact factors of the quality of ultrasound-guided fine needle aspiration(US-FNA) specimens of thyroid nodules. Methods Totally 436 thyroid nodules in 388 patients who underwent US-FNA were enrolled and divided into superior diagnosis group(n=325) and non-superior diagnosis group(n=111) according to background clot or blood, number of obtained cells, preserved tissue architecture and cellular degeneration of US-FNA specimen. Ultrasonic characteristics were observed and compared between groups, including the maximum diameter, shape, boundary, echo, calcification and blood supply of thyroid nodules. The impact factors of the quality of US-FNA specimens were analyzed. Results There were significant differences of the maximum diameter, internal calcification and Adler blood supply between groups(all P<0.05). The maximum diameter and calcification of thyroid nodules were impact factors of the quality of US-FNA specimens(P=0.010, 0.002). Conclusion The maximum diameter and calcification of thyroid nodules shown by ultrasound were impact factors of the quality of US-FNA specimens.
作者 陈曦 陶玲玲 詹维伟 李伟伟 樊金芳 吴敏 周伟 CHEN Xi;TAO Lingling;ZHAN Weiwei;LI Weiwei;FAN Jinfang;WU Min;ZHOU Wei(Department of Ultrasound,Luwan Branch,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200020,China;Department of Ultrasound,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,China;Department of Pathology,Luwan Branch,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200020,China)
出处 《中国介入影像与治疗学》 北大核心 2022年第8期463-466,共4页 Chinese Journal of Interventional Imaging and Therapy
关键词 甲状腺结节 活组织检查 针吸 超声检查 thyroid nodule biopsy needle ultrasonography
  • 相关文献

参考文献1

二级参考文献17

  • 1李文波,朱庆莉,张波,姜玉新,杨堤.超声引导下细针吸取细胞学检查对甲状腺结节的诊断价值[J].中国医学科学院学报,2010,32(1):76-80. 被引量:45
  • 2Polyzos SA, Anastasilakis AD. Clinical complications fol- lowing thyroid fine-needle biopsy: a systematic review[J]. Clin Endocrinol (Oxf),2009,71(2):157-165.
  • 3Polyzos SA, Anastasilakis AD. Systematic review of cases reporting blood extravasation-related complications after thyroid fine-needle biopsy[J]. J Otolaryngol Head Neck Surg,2010,39(5):532-541.
  • 4Donatini G, Masoni T. Is fine-needle aspiration cytology for thyroid nodules a routine and safe procedure? A se- ries of emergency eervieotomies following FNAB[J]. Lan- genbecks Arch Surg,2010,395(7):873-876.
  • 5Noordzij JP, Goto MM. Airway compromise caused by hematoma after thyroid fine-needle aspiration[J]. Am J Otolaryngol,2005,26(6):398-399.
  • 6Erdogan MF, Anil C, Cesur M, et al. Color flow Doppler sonography for the etiologic diagnosis of hyperthyroidism [J]. Thyroid,2007,17(3):223-228.
  • 7Musharrafieh UM, Nasrallah MP, Sawaya RA, et al. Chemical neuritis after fine needle aspiration biopsy of thyroid nodule[J]. J Endocrinol lnvest,2006,29(10):947- 948.
  • 8Anastasilakis AD, Polyzos SA, Nikopoulos P. Suben- dothelial carotid hematoma after fine needle aspiration biopsy of a solitary thyroid nodule[J]. J Ultrasound Med, 2008,27(10):1517-1520.
  • 9Celik H, Yucel C, Oktar S, et al. Iatrogenic pseudoa- neurysm of the superior thyroid artery: color Doppler ul- trasonographic diagnosis and treatment approach[J]. J Ultrasound Med,2004,23(12): 1675-1678.
  • 10Newkirk KA, Ringel MD, Jelinek J, et al. Ultrasound- guided fine-needle aspiration and thyroid disease[J]. Otolaryngology Head Neck Surgery,2000,123(6):700-705.