摘要 AIM:To explore the possibility of deploying three contactless devices(static and rotating Scheimpflug technology,spectral domain optical coherence tomography)for measuring central corneal thickness(CCT)in preoperative and postoperative examinations of cataract patients.METHODS:Totally 72 patients who had undergone surgery without complications were selected.The CCT was measured prior to the operation,as well as on the first,5th-7th and 28th day following the operation using the Nidek NT 530-P,Sirius?,and Topcon OCT-2000 devices.RESULTS:A significant postoperative increase and subsequent decrease in CCT was identified with all three devices.The correlations were highly significant and thus reflect a very good degree of comparability at all times with the exception of the rotating Scheimpflug camera.The postoperative results from the latter differed significantly from the other devices.The correlations were Sirius/Topcon(P=0.010)and Sirius/Nidek(P<0.0005).No statistically significant difference could be identified in the comparison between Topcon and Nidek(P=0.056).CONCLUSION:All three devices are suitable for postoperative monitoring of CCT.The measurement results are only comparable to a limited extent and not interchangeable in the course of treating a single patient.This is due to the different imaging technology used in the devices and the resulting modalities for conducting the measurements.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第8期1266-1272,共7页 国际眼科杂志(英文版)
  • 相关文献

参考文献1

二级参考文献31

  • 1Lai-Yong Tai,Keat-Ween Khaw,Choung-Min Ng,Visvaraja Subrayan.Central Corneal Thickness Measurements With Different Imaging Devices and Ultrasound Pachymetry[J]. Cornea . 2013 (6)
  • 2Bengu E. Koktekir,Sansal Gedik,Berker Bakbak.Comparison of Central Corneal Thickness Measurements With Optical Low-Coherence Reflectometry and Ultrasound Pachymetry and Reproducibility of Both Devices[J]. Cornea . 2012 (11)
  • 3Wuhe Chen,Colm McAlinden,Konrad Pesudovs,Qinmei Wang,Fan Lu,Yifan Feng,Jie Chen,Jinhai Huang.Scheimpflug–Placido topographer and optical low-coherence reflectometry biometer: Repeatability and agreement[J]. Journal of Cataract & Refractive Surgery . 2012 (9)
  • 4Se-Hoon Park,Suk-Kyue Choi,Doh Lee,Eun-Jung Jun,Jin-Hyoung Kim.Corneal Thickness Measurement Using Orbscan, Pentacam, Galilei, and Ultrasound in Normal and Post-Femtosecond Laser In Situ Keratomileusis Eyes[J]. Cornea . 2012 (9)
  • 5Emmanuel Guilbert,Alain Saad,Alice Grise-Dulac,Damien Gatinel.Corneal thickness, curvature, and elevation readings in normal corneas: Combined Placido–Scheimpflug system versus combined Placido–scanning-slit system[J]. Journal of Cataract & Refractive Surgery . 2012 (7)
  • 6Haya Alfarhan,Al-Otaibi.Comparison of central corneal thickness measurements using ultrasound pachymetry, ultrasound biomicroscopy, and the Artemis-2 VHF scanner in normal eyes[J]. Clinical Ophthalmology . 2012 (default)
  • 7Jinhai Huang,Giacomo Savini,Liang Hu,Kenneth J. Hoffer,Weicong Lu,Yifan Feng,Feng Yang,Xiuli Hu,Qinmei Wang.Precision of a new Scheimpflug and Placido-disk analyzer in measuring corneal thickness and agreement with ultrasound pachymetry[J]. Journal of Cataract & Refractive Surgery . 2012
  • 8Alberto López-Miguel,María Encarnación Correa-Pérez,Silvia Miranda-Anta,Darío Iglesias-Corti?as,María Bego?a Coco-Martín,Miguel J. Maldonado.Comparison of central corneal thickness using optical low-coherence reflectometry and spectral-domain optical coherence tomography[J]. Journal of Cataract & Refractive Surgery . 2012 (5)
  • 9Ravaughn Williams,Barbara A Fink,P Ewen King-Smith,G Lynn Mitchell.Central Corneal Thickness Measurements: Using an Ultrasonic Instrument and 4 Optical Instruments[J]. Cornea . 2011 (11)
  • 10Akihiro Ishibazawa,Sho Igarashi,Kazuomi Hanada,Taiji Nagaoka,Satoshi Ishiko,Haruna Ito,Akitoshi Yoshida.Central Corneal Thickness Measurements With Fourier-Domain Optical Coherence Tomography Versus Ultrasonic Pachymetry and Rotating Scheimpflug Camera[J]. Cornea . 2011 (6)

共引文献8

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部