金属氧化物避雷器的残压检测模型

Residual Voltage Detection Model of Metal Oxide Surge Arrester
下载PDF
导出
摘要 为了延缓金属氧化物避雷器(MOSA)阀片的寿命,保障电力系统安全稳定运行,提出了基于残压检测的避雷器诊断方法。将MOSA在冲击电流作用下产生的残压信号作为研究对象,建立MOSA残压检测模型;利用有限元法(FEM)得到残压检测结构参数,证明了该检测模型不会对MOSA产生不良影响。对模型进行工频稳态数值仿真,结果表明所提出的MOSA残压检测模型不仅可以降低MOSA本体的最大场强,还可以降低MOSA的工频损耗,延缓结构老化,降低设备的事故率。 This paper proposed a residual voltage detection method for MOSA to slow down the service life of the MOSA valve plate and ensure the safe and stable operation of the power system.It took the residual voltage signal generated by MOSA under the action of impulse current as the research object and established the residual voltage detection model of MOSA.Moreover,it employed FEM to obtain the structure parameters of residual voltage detection and proved the detection model would not have adverse effects on MOSA.This research used this model to do the simulation experiment of power frequency steady-state numerical value.The results show that the proposed residual voltage detection model could help reduce the maximum electric field strength,decrease the power frequency loss,delay the aging of the structure,and lower the accident rate of the equipment.
作者 李明远 潘仁东 周健 钱俊杰 邱伊云 LI Ming-yuan;PAN Ren-dong;ZHOU Jian;QIAN Jun-jie;QIU Yi-yun(Jiangsu Power Transmission&Transformation Co.,Ltd,Nanjing 211102,China;School of Electric Power Engineering,Nanjing Institute of Technology,Nanjing 211167,China)
出处 《电工电气》 2022年第8期53-57,共5页 Electrotechnics Electric
关键词 金属氧化物避雷器(MOSA) 残压检测 故障诊断 残压信号 过电压 metal oxide surge arrester(MOSA) residual voltage detection fault diagnosis residual voltage signal overvoltage
  • 相关文献

参考文献10

二级参考文献94

  • 1戴玲,林福昌,朱志芳,李劲.高储能密度陶瓷电容器电气性能研究[J].高电压技术,2004,30(10):49-51. 被引量:5
  • 2舒印彪.中国直流输电的现状及展望[J].高电压技术,2004,30(11):1-2. 被引量:236
  • 3车文俊,李凡,何计谋,苏淼.高压直流金属氧化物避雷器国产化的关键技术及现状[J].电瓷避雷器,2005(3):29-31. 被引量:14
  • 4Shu Yinbiao. Current status and development of national grid in China[C]//2005 IEEE/PES T&D Conference. Dalian, China, 2005.
  • 5CIGRE Working Group 38. 04. Ultra high voltage technology [R]. CIGRE, 1994: 37/38-01.
  • 6刘振亚,舒印彪,刘泽洪,等.特高压交流输电技术研究成果专辑(2005年)[M].北京:中国电力出版社,2005:69-282.
  • 7刘振亚,舒印彪,孙听,等.特高压交流输电技术研究成果专辑(2007年)[M].北京:中国电力出版社,2007:32-255.
  • 8CIGRE WG 31-04. Electric power transmission at voltage of 1000kV and above, plans for future ac and dc transmission, data on technical and feasibility and on general design, information on testing facilities and the research in progress[J]. Electra, 1983, 91(12).. 83-133.
  • 9GB311.1-1997高压输变电设备的绝缘配合[S].北京:中国标准出版社,1997.
  • 10刘振亚,陈维江,谷定燮,等.特高压交流输电技术丛书特高压交流输电系统过电压和绝缘配合[M].北京:中国电力出版社,2008:9.80.