摘要 详细介绍了某电厂锅炉进入深调负荷时,氮氧化物生成量急剧升高,从生成机理上和当前锅炉运行参数上进行了分析,并对同类型机组进行比较,找出了氮氧化物升高的原因。 It introduces in detail that when the boiler of a power plant enters the deep load regulation,the nitrogen oxide production in⁃creases sharply.It analyzes the generation mechanism and the current boiler operation parameters,and finds out the reason of the in⁃crease of nitrogen oxide by comparing the two same type units.
作者 邴长江 关风一 王博 徐绍宗 李闯 BING Changjiang;GUAN Fengyi;WANG Bo;XU Shaozong;LI Chuang(China Energy Group Kangping Power Generation Co.,Ltd.,Shenyang,Liaoning 110500,China;Electric Power Research Institute of State Grid Liaoning Electric Power Co.,Ltd.,Shenyang,Liaoning 110006,China;Liaoning Dongke Electric Power Co.,Ltd.,Shenyang,Liaoning 110179,China)
出处 《东北电力技术》 2022年第7期55-59,共5页 Northeast Electric Power Technology
关键词 锅炉 深度调峰 NO_(x) boiler deep peak⁃shaving NO_(x)