期刊文献+

660 MW超超临界机组启动疏水降噪分析及优化

Analysis and Optimization of Drain and Noise Reduction at Start Up of 660 MW Ultra Supercritical Unit
下载PDF
导出
摘要 针对某660 MW超超临界锅炉启动时,大气扩容器排汽过程产生强烈噪音的问题,经过分析提出了降噪方案:增设减温水,减少排汽量;加装消音器,降低声功率级。在某电厂使用后,取得了明显的效果。可以为同等机组的优化设计及电厂运行人员提供参考。 When the 660 MW ultra supercritical boiler starts up,the steam discharging process of the atmospheric flash tank generates loud noises.After analysis,a noise reduction plan was proposed:adding desuperbeating water to reduce exhaust steam;installing a silencer to reduce sound power level.After this plan was used in a power plant,significant results have been achieved.It can provide reference for the optimization design of the same unit and power plant operators.
作者 张尧 ZHANG Yao(Shanghai Boiler Works Co.,Ltd.,Shanghai 200245,China)
出处 《锅炉技术》 北大核心 2022年第4期14-17,30,共5页 Boiler Technology
关键词 超超临界锅炉 启动系统 噪声 大气扩容器 ultra supercritical boiler start up system noise atmospheric flash tank