随着各种电气设备在医院诊疗中的使用,谐波源越来越多,通过分析谐波的产生以及形成危害的原因,减少对线路及电源处造成的谐波污染,通过提出一种谐波治理方案,加装谐波保护柜,实现保障电动机设备用电环境等多方面的治理效益,以期达到全面谐波治理的效果。
With the use of various electrical equipment in hospital diagnosis and treatment, there are more and more harmonic sources.By analyzing the causes of harmonic generation and harm, we can reduce the harmonic pollution caused to the line and power supply.By proposing a harmonic treatment scheme and installing harmonic protection cabinet, we can realize the treatment benefits of ensuring the electrical environment of motor equipment and other aspects, in order to achieve the effect of comprehensive harmonic treatment.
作者
陈义清
CHEN Yiqing(Tongji Architectural Design(Group)Co.,Ltd.,Shanghahi 200092,China)
出处
《现代建筑电气》
2022年第6期48-51,共4页
Modern Architecture Electric
关键词
谐波
危害
电力侧
治理
谐波保护器
harmonic
damage
power side
compensation
harmonic protector