期刊文献+

LNG罐内泵间歇性振动尖峰故障分析与应对措施

Analysis and disposal of LNG in-tank pump’s intermittent vibration spike faults
下载PDF
导出
摘要 对某液化天然气(LNG)接收站罐内泵投用试车期间发生的间歇性振动尖峰故障现象进行了描述,对产生该故障的原因进行了分析。对照拆解结果,对分析的可能原因进行了确认,发现轴向力平衡机构中平衡盘与末级挡板间隙过小是造成间歇性振动尖峰发生的直接原因。并在此基础上,提出了该故障的处置措施。经现场实际测试,证明该处置措施有效可行,可为LNG低温泵类似问题提供借鉴。 The intermittent vibration spike fault phenomenon that occurred during the commissioning of an LNG in-tank pump of an LNG receiving terminal is described,and the cause of the fault is analyzed. The possible causes of the analysis were confirmed against the disassembly results,and it was found that the gap between the balance plate and the last-stage bezel in the axial force balancing mechanism was too small,which caused the intermittent vibration spike. On this basis,the disposal measures of the fault are put forward. The practical test on the site proves that the disposal measure is effective and feasible,which can provide reference for similar problems of LNG cryogenic pumps.
作者 郑元杰 Zheng Yuanjie(Sinopec Qingdao LNG Co.,Ltd.,Qingdao Shandong 266400)
出处 《石化技术》 CAS 2022年第7期49-51,共3页 Petrochemical Industry Technology
关键词 LNG 罐内泵 振动 LNG in-tank pump vibration
  • 相关文献

参考文献6

二级参考文献40

共引文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部